Incubators

Models

Incubatore ICF 55 PLUS a ventilazione forzata

ICF 120 PLUS- forced air Incubator, capacity 120 LT, with 7 programs x 10 steps

Working range: 5 °C above ambient temperature up to 80 °C. Net volume 120 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 3.1: fluid expansion limiter for max temperature. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 810 x 750 x 690mm. Weight 74 Kg. 230V / 600 W. 
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 steps each (temperature, time, fan speed) and a further basic program with a single operating step (temperature, time). Special program for sterilization at 130 °C.
Packaging and transport included.

ICF 200 PLUS - forced air Incubator, capacity 200LT, with 7 programs x 10 steps

Working range: 5 °C above ambient temperature up to 80 °C. Net volume 200 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 3.1: fluid expansion limiter for max temperature. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 945 x 870 x 755mm. Weight 103 Kg. 230V / 700W. 
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 steps each (temperature, time, fan speed) and a further basic program with a single operating step (temperature, time). Special program for sterilization at 130 °C.
Packaging and transport included.

ICF 400 PLUS- forced air Incubatorn, capacity 400LT, with 7 programs x 10 steps

Working range: 5 °C above ambient temperature up to 80 °C. Net volume 400 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 3.1: fluid expansion limiter for max temperature. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 1285 x 1000 x 750 mm. Weight 160 Kg. 230V / 1500W. 
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 steps each (temperature, time, fan speed) and a further basic program with a single operating step (temperature, time). Special program for sterilization at 130 °C.
Packaging and transport included.

Incubatore ICF 55 SUPER a ventilazione forzata

ICF 120 SUPER - forced air Incubator, capacity 120 LT, with touch scree n

Working range: 5 °C above ambient temperature up to 80 °C. Net volume 120 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 3.1: fluid expansion limiter for max temperature. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 810 x 750 x 690mm. Weight 74 Kg. 230V / 600 W. 
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Version, color touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time, fan speed) and a further basic program with a single operating step (temperature, time, fan speed). Special program for sterilization at 130 °C. Recording of working data without limit on USB stick supplied.
Packaging and transport included.


ICF 200 SUPER- forced air Incubator, capacity 200LT, with touch screen

Working range: 5 °C above ambient temperature up to 80 °C. Net volume 200 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 3.1: fluid expansion limiter for max temperature. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 945 x 870 x 755 mm. Weight 103 Kg. 230V / 700W. 
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Versioncolor touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time, fan speed) and a further basic program with a single operating step (temperature, time, fan speed). Special program for sterilization at 130 °C. Recording of working data without limit on USB stick supplied.
Packaging and transport included.

ICF 400 SUPER- forced air Incubator, capacity 400LT, with touch screen

Working range: 5 °C above ambient temperature up to 80 °C. Net volume 400 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 3.1: fluid expansion limiter for max temperature. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 1285  x 1000 x 750 mm. Weight 103 Kg. 230V / 1500W. 
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Versioncolor touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time, fan speed) and a further basic program with a single operating step (temperature, time, fan speed). Special program for sterilization at 130 °C. Recording of working data without limit on USB stick supplied.
Packaging and transport included.

ICN 16 PLUS - Natural Incubator, capacity 16LT, with 7 programs x 10 st eps

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 16 Litres. Temperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with two wire shelves. External dimensions (width x height x depth): 530 x 370 x 400 mm. Weight 23 Kg. 230V / 85 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 steps each (temperature, time) and a further basic program with a single operating step (temperature, time).
Packaging and transport included.

ICN 35 PLUS- Natural Incubator, capacity 35LT, with 7 programs x 10 ste ps

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 35 Lt. Temperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with two wire shelves. External dimensions (width x height x depth): 620 x 440 x 460 mm. Weight 33 Kg. 230V / 125 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 steps each (temperature, time) and a further basic program with a single operating step (temperature, time).
Packaging and transport included.

ICN 55 PLUS- Natural Incubator, capacity 55LT, with 7 programs x 10 ste ps

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 55 litres. Temperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with two wire shelves. External dimensions (width x height x depth): 660 x 500 x 545 mm. Weight 42 Kg. 230V / 250 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 steps each (temperature, time) and a further basic program with a single operating step (temperature, time).
Packaging and transport included.

ICN 120 PLUS- Natural Incubator, capacity 120LT, with 7 programs x 10 s teps

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 120 litres. Temperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 780 x 610 x 645 mm. Weight 61 Kg. 230V / 350 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 steps each (temperature, time) and a further basic program with a single operating step (temperature, time).
Packaging and transport included.

ICN 200 PLUS- Natural Incubator, capacity 200LT, with 7 programs x 10 s teps

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 200 litres. Temperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 875 x 755 x 710 mm. Weight 77 Kg. 230V / 600 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

Plus Version, 7 programs that can be memorized with 10 each (temperature, time) and a further basic program with a single operating step (temperature, time).
Packaging and transport included.

ICN 16 SUPER - Natural Incubator, capacity 16LT, with touch screen

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 16 Litres. Temperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with two wire shelves. External dimensions (width x height x depth): 530 x 370 x 400 mm. Weight 23 Kg. 230V / 85 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Version, color touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time) and a further basic program with a single operating step (temperature, time). Recording of working data without limit on USB stick supplied.
Packaging and transport included

ICN 35 SUPER - Natural Incubator, capacity 35LT, with touch screen

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 35 LitresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with two wire shelves. External dimensions (width x height x depth): 620 x 440 x 460 mm. Weight 33 Kg. 230V / 125 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Version, color touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time) and a further basic program with a single operating step (temperature, time). Recording of working data without limit on USB stick supplied.
Packaging and transport included.

ICN 55 SUPER- Natural Incubator, capacity 55LT, with touch screen

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 55 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with two wire shelves. External dimensions (width x height x depth): 660 x 500 x 545 mm. Weight 42 Kg. 230V / 250 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Version, color touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time) and a further basic program with a single operating step (temperature, time). Recording of working data without limit on USB stick supplied.
Packaging and transport included.

ICN 120 SUPER- Natural Incubator, capacity 120LT, with touch screen

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 120 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 780 x 610 x 645 mm. Weight 61 Kg. 230V / 350 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Version, color touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time) and a further basic program with a single operating step (temperature, time). Recording of working data without limit on USB stick supplied.
Packaging and transport included

ICN 200 SUPER- Natural Incubator, capacity 200LT, with touch screen

Working range: 5 °C above ambient temperature up to 70 °C. Net volume 200 litresTemperature variation at 37 °C: ± 0.3 °C, uniformity of the temperature at 37 °C: ± 0.4 °C. Stainless steel door with wide glass window. Digital PID controller system with limited number of adjustment keys for easy parameter setting. Wide backlit LCD display for simultaneous reading of the set temperature, the real one, and all other operating parameters. Visual and audible Alarm be disable by the operator. Digital timer with range of programming 1 min - 99 h and 59 min. and continuous function. Possibility to set a delay in the start of the heating cycle. Temperature limiter adjustable work by the operator for the protection of the samples (function 'safe temperature').

Safety Class 2.0 with double digital limiters of temperature and additional fluid expansion limiter. Passage hole of 5 mm diameter on the roof as standard for insertion of an external temperature sensor to control or to certificate of the internal temperature. Stainless steel chamber with supports for the shelves completely removable for easy cleaning. Supplied with three wire shelves. External dimensions (width x height x depth): 875 x 755 x 710 mm. Weight 77 Kg. 230V / 600 W. The power consumed by this model is the lowest of the whole category and saves 50% energy with the same heating times.
Supplied with calibration report at 37 °C, executed with instrument Accredia certificated.

SUPER Version, color touch screen display, 8 programs that can be memorized with 8 steps each (temperature, time) and a further basic program with a single operating step (temperature, time). Recording of working data without limit on USB stick supplied.
Packaging and transport included.

Accessories

Steel wire shelf for Incubator ICN 16

Steel wire shelf for Incubator ICN 35

Steel wire shelf for Incubator ICN 55

Steel wire shelf for Incubator ICN 120

Steel wire shelf for Incubator ICN 200